Product information " PIR, Vibration and Temperature Sensor "

The combined infrared, vibration and temperature sensor is easily connected via the RJ-12 patch cable into one of the two CAN ports on the Didactum base systems. This two meter RJ-12 cable is included. You can also extend this sensor up to 200 meters from the Didactum monitoring system. If more coverage is required for the detection of movement, vibration, or your temperature monitoring then you can easily connect these sensors in series. If desired, you can enter these combined sensors into the integrated map feature of the Didactum alarm and monitoring system for enhanced visual alerts.

Ideal for the security and environmental monitoring of large infrastructures, such as data centers.
Smart multi monitoring

Addressable sensor let you remotely monitor movement, temperature and vibration in any location in the data center from internet

Embedded temperature sensor

Allows you to measure temperature without additional sensors

CAN ports

Simplifies installation and management by connecting to any other extension units or to master unit directly

Security

Sensor provides 3-level user authentication

Easy Installation

Simply connect sensor to any CAN output. Processors - we use NXP

Description

Sensor is needed for control of movement over an infra-red range and measurement of temperature and vibration indoors. Max. distance from the monitoring unit is 200 meters.
Technical specifications
Viewed angle 110°
Max. distance 12 m
Measured range of temperature -20… +60°С
Accuracy 1°С
Maximum distance 200 meters
Features  
Customs code 8531 10 950 1
Mounting There are mounting slot on the bottom of the case for fastening. Fasten sensor, connect RJ11 connector to the input of the previous CAN unit, sensor or of the monitoring unit. The red LED lights up.
Match the bus terminators of the CAN units. Switch terminator TR in ON position on the monitoring unit and on the last CAN unit or this sensor, TR on intermediate CAN units are in Off (1,2) position. Maximum 8 CAN units, sensors and/or devices can be on one CAN bus.
Connection To connect sensor unit to the system, log into the interface -> Preferences -> Can Config -> CAN1 or CAN2 (depends on which physical port CAN1 or CAN2 of the system the unit is connected).
Click Config button and wait. The system will poll the bus CAN and give rows with data, if successful will write: Done!. CAN modules and sensors will appear in the list. Click Apply and then click Restart.
Go to --> System Map / Floor Map, click Refresh button, or wait, new devices and new sensors will appear in the tree. Green LED will light up when CAN sensor is connected and successfully determined by the system.
Connection is not successful if after clicking Config, the poll is reset before the phrase "Updating". Check whether terminators on the bus line are set in the right position, change their position using TR switch if needed.
Supply includes Sensor, built in 3-wired shielded patch cable RJ12 (2m), screws, plastic bracket, manual.
Net weight 130g
Dimensions (LHW) 105×57×40mm